<LOGO>
FM Transmitter Measurement Report
Created: 2025-01-07 15-52-24
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
96.90 MHz 5/5, 59 dBuV VOLTAGE
Pilot RDS Phase Difference
7.1 kHz 3.4 kHz 24 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
11 kHz 74 kHz 10120 2,0455
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,0 dBr
MIN AVE MAX % above 10,0 dBr
6,6 dBr 7,88 dBr 8,6 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"VOLTAGE " FE45 10 (Pop M) 1 0 0 5 15:52, 7.01.2025
RT
"VOLTAGE - Dance music "
AF EON
96.9, 102.9 MHz -
FM Scope Station: 96.90 MHz, signal: 5/5 (60 dBuV) Max at: 74 kHz MIN: 11 kHz % above 75 kHz: 2,0455 Acquired: 2025/01/07 15:51:20 Total samples: 10120 Equivalent time: 0:08:26 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 2000 4000
FM Scope MAX: 8,6 dBr MIN: 6,6 dBr AVE: 7,88 dBr % above 10,0 dBr: 0,0 Last value: 7,7 dBr (2025/01/07 15:51:20) Station: 96.90 MHz, signal: 5/5 (60 dBuV) 15:44 15:45 15:46 15:47 15:48 15:49 15:50 15:51 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality